Definitive Irish ICF Water Ingress Guide

    Why is my ICF house leaking?

    You have a damp patch. You have chased it. The silicone seal has failed twice. You are frustrated. ICF window sill water leakage is one of the most annoying issues on site. It is difficult to trace.

    The Central Thesis

    ICF is a single skin wall. There is no cavity. There is no DPC tray behind the render to catch water that gets past the outer face. That is the whole reason why you have an ICF leak but cannot find where it started. Once water gets behind the outer EPS face at any junction, it travels. It tracks down the concrete core. It can emerge on the inside far from where it entered. Installers chase the damp patch under a window. But the real breach is at a parapet three metres away.

    It is a junction detail problem. The same root cause shows up at several points. Every junction has to shed water on its own. Nothing behind it will save you.

    The Five Critical Above-Grade Junctions

    1

    Window Reveals & Sills

    This is the most common place for water coming through at sill level. Water coming in under windows ICF is rarely a frame failure. It is a reveal detail problem.

    Sills are too short. They lack a drip groove. They have failed end caps. Or the DPC sequence is wrong. Sometimes the DPC is cracked behind the sill. A damaged barrier lets water track straight into the foam.

    The Fix: Custom folded 2mm aluminium sills. They feature welded upstands and end caps. They include a DPC tray. They extend 40mm past the finished render.

    2

    Door Thresholds & Reveals

    Doors share the same single skin geometry as windows. They fail the same way. But they are often overlooked.

    Your thresholds should match your window cills. They should come from the same supplier. They should use the same material, colour, and detail. This creates a continuous weather envelope.

    The Fix: Order thresholds and window cills together to guarantee matching colour and watertight connection.

    3

    Parapets & Flat Roofs

    An ICF parapet leaking is a serious issue. Where the flat roof meets the wall, the capping is your only defence.

    An undersized capping lets water track down behind the render at the wall head.

    The Fix: Made to measure aluminium parapet cappings from Cills.ie seal these vulnerable heads permanently.

    4

    Abutments & Flashings

    Canopies, balconies, and lower roofs abut the ICF wall. Water pools at these junctions.

    A mastic smear will not hold.

    The Fix: Precision aluminium flashings shed the water clear of the render face.

    5

    Rainwater Goods Discharge

    Overflowing gutters dump massive volumes of water. This water drives straight at the render face.

    It quickly finds the nearest weak junction.

    The Fix: Premium aluminium rainwater goods keep water off the wall face.

    How to order cills on the CILLS app

    Watch our system demonstration video. The Cills app guides you through measuring, manufacturing, and fitting.

    • 1Create a free account at app.cills.ie.
    • 2Select your ICF system (Amvic, Castleforms, BuildBlock, ThermoHouse, or Nudura).
    • 3Select your specific block configuration. The app preloads the core and EPS insulation values.
    • 4Input your measured window frame width, render thickness, and cill overhang (we recommend 40mm).
    • 5The app calculates the precise target depth. Confirm your order details, select your RAL colour, and submit.

    ICF Sill Preparation & Sealing Protocol

    A premium sill requires correct site preparation to function as a system. If the preparation is done poorly, the detail will leak. Follow these steps to prepare your reveals and install the cills.

    Step 1: Trimming the EPS

    Cut the outer EPS foam block below the window frame level. Create a minimum 7 degree fall sloping outward. The surface must be clean, flat, and free of loose foam beads. Do not leave the EPS flat.

    Step 2: Install the Continuous DPC Tray

    Lay a continuous DPC membrane across the prepared EPS bed. This membrane must extend underneath the window frame. It must also lap up the sides of the window reveals by at least 150mm on each side. This creates a secondary watertight pocket.

    Step 3: Sealing the Window Reveals

    The window frame must be sealed to the ICF block opening reveals. Apply a continuous bead of high performance polymer adhesive. Never use cheap silicone. This forms a primary weather seal. Seal the outer window frame boundaries to the reveals. Ensure the seal links back to the structural concrete core.

    Step 4: Positioning the Welded Upstand

    Slide the welded upstand of the Cills.ie aluminium sill behind the window frame. Ensure the upstand sits securely. The upstand must never block the window drainage slots. Fasten the cill using the pre drilled fixing holes.

    Step 5: Render Interface & Weep Holes

    Place the return landing of the cill flush on the render basecoat. Overlap the joint with render mesh. Ensure the front drop clears the finished render face by 40mm. Make sure the side weep holes are clear to drain the pocket.

    The Cills.ie System Specification

    To guarantee performance, the window sill must match the Cills.ie system specification. Generic sills or site bent profiles do not feature the correct geometry. They lack welded upstands, drip notches, and integrated weep holes. Using alternative specifications voids the system warranty.

    System Materials & Geometry

    • Fabricated from 2mm architectural aluminium sheet
    • Welded upstands and returns for absolute joint security
    • Polyester powder coated finish to matching RAL colours

    Critical Clearances

    • 40mm minimum projection clear of finished render face
    • Built in 7 degree slope to ensure rapid water shedding
    • Drip notch underneath to stop water tracking backward

    Above-Grade vs Below-Grade Waterproofing

    We are honest about ICF water issues. Cills.ie provides solutions for above grade water shedding junctions. This includes window and door cills, parapet cappings, wall flashings, and rainwater goods. We design these with full solution authority.

    We do not claim our sills or trims fix below grade foundation waterproofing issues. They do not fix honeycombing in the concrete pour. They do not stop hydrostatic basement leaks.

    These issues represent a separate class of ICF leak. They require a waterproofing membrane and a drainage specialist. They cannot be solved with an aluminium sill. Knowing this distinction is critical for architects and contractors.

    Service Order Guarantee

    We support you through every stage of your build. Our service covers:

    1. 1Measuring guidance on site
    2. 2Precision manufacturing in Dublin
    3. 3Fitting support for your crew
    Are you an architect or developer? You can view the full specification detail for architects and specifiers on fabricator.ie to review detailed cross sections.
    On-Site Trade Service & Physical Samples

    We Can Visit Your Site to Measure & Provide Samples

    Need exact measurements on your ICF build? We visit active construction sites across Ireland to take opening dimensions, check reveal preparation, and provide physical aluminium colour and profile samples before folding in our Dublin workshop.

    Measuring on-site ICF window cills for Castleforms block in Blessington
    Castleforms Job — Blessington
    Blessington, Co. Wicklow
    Castleforms ICF Block

    Site Survey & Measuring in Blessington

    We visited this active ICF residential build in Blessington using the Castleforms block system. We measured every opening on site, verified the outer EPS leaf thickness and concrete core landing, and provided physical aluminium colour and profile samples before fabrication.

    Exact mm on-site measuring
    Measuring ICF window cills on-site for 300mm Amvic block in Portlaoise
    Amvic 300mm Job — Portlaoise
    Portlaoise, Co. Laois
    300mm Amvic ICF Block

    Site Survey & Measuring in Portlaoise

    On-site measuring and sample handover for a live ICF project in Portlaoise built with 300mm Amvic blocks. We checked the window reveal setbacks, confirmed render allowances, and ensured the 40mm anti-capillary drip cleared the finished external wall face perfectly.

    Exact mm on-site measuring

    Book an On-Site ICF Measure & Sample Drop

    Building with Amvic, Castleforms, BuildBlock, ThermoHouse, or Nudura? We visit your site in Dublin, Kildare, Laois, Wicklow, and nationwide to verify your openings and drop physical samples before folding.

    Frequently Asked Questions

    Get Your ICF Sill Fixed permanently

    Order your made to measure aluminium cills in the CILLS app or call us directly. We will ensure you get the exact size you need to clear the render and prevent leaks.