    How to measure aluminium window cills

    Accurate site measurement guarantees a perfect drop-in fit for your made-to-measure aluminium window cills. Follow this step-by-step contractor guide to record width, projection, and upstands.

    Workshop & Trade Counter: Unit 20, Westlink Industrial Estate, Kylemore Road, Inchicore, Dublin 10, D10 TD35 | Phone: +353 1 223 8774 | Lead Time: 5–7 business days.

    Official Cills.ie Measuring Guide — Standard Aluminium Window CillsWatch directly on YouTube
    Video Guide • No Drawing Needed

    How to Measure a Standard Aluminium Window Cill (No CAD Drawing Needed)

    Other aluminium suppliers ask for technical CAD drawings before quoting. At Cills.ie, you simply measure your window opening on site and enter three profile dimensions plus length directly into our 3D app:

    A
    Dimension A — Rear Upstand: The vertical back lip (typically 15mm–30mm) that tucks into the window frame sill rebate or against the frame base.
    B
    Dimension B — Cill Projection (Depth): The horizontal projection from the window frame out past the external render or insulation face (including a 40mm–50mm overhang).
    K
    Dimension K — Front Drip Nose: The downturned front edge and kick-back drip detail (typically 25mm–40mm) that sheds rainwater clear of the wall.

    4-Step Window Cill Measurement Procedure

    1

    Measure Reveal Width (Length)

    Measure the brick-to-brick or render-to-render opening width at the window subframe and at the outer wall edge. Note the smallest dimension in millimetres.

    Pro Tip: State whether your figure is the masonry opening size (we allow 3mm clearance per side) or total finished cill length.
    2

    Measure Projection Depth

    Measure from the window frame fixing groove / subframe to the outer finished masonry or render line. Add a minimum of 35mm to 45mm forward overhang to create an effective drip.

    Pro Tip: On EWI projects, remember to include insulation thickness + adhesive basecoat (typically 100mm–160mm additional depth).
    3

    Determine Rear Upstand Height

    The rear vertical upstand tucks underneath the window frame sill groove or beds against airtight membranes. Standard rear upstands are 20mm to 25mm.

    Pro Tip: For deep retrofit and ICF trays, vertical upstands from 50mm to 75mm can be specified.
    4

    Confirm Front Drip & Stop-Ends

    Standard front drip face is 30mm–40mm with a 10mm anti-capillary return. Specify welded stop-end heights (25mm–50mm) to embed cleanly into side reveal render beads.

    Pro Tip: Welded stop-ends prevent water from bypassing around the cill into reveal insulation.
    Common Site Measuring Mistakes to Avoid
    • 1. Forgetting Render ThicknessAdding external insulation without factoring in the 6–10mm basecoat and acrylic render topcoat results in insufficient drip projection.
    • 2. Measuring Only One PointOlder window reveals are rarely parallel. Always take measurements at both rear and front reveal edges.
    • 3. Insufficient Fall AngleEnsure the sill bedding has a minimum 7° slope to prevent standing water during heavy Irish driving rain.
    • 4. Ignoring Thermal BreaksAluminium is conductive. Always leave clearance beneath the cill for continuous structural insulation or thermal pads .